Finned tube air heat exchangers
With an Alfa Laval finned tube air heat exchanger you get a robust cooler that will deliver high performance for many years to come. Our product range covers most applications in oil & gas, data centers, hydrogen, RNG and CCUS. We supply both standardized and fully customized, engineered-to-order solutions. Thanks to their flexible designs, we can configure our heat exchangers to match your specific operating conditions, ensuring reliable operation, low operating costs and high performance.
Benefits of air-cooled finned tube heat exchangers
- Customized to your requirements
- Very low energy consumption
- Robust heat exchangers, built for tough duties
- High performance
- Low maintenance requirements
Discover our range of tailored air-cooling solutions
Documentos
Fale com um especialista
Ficaremos felizes em discutir os benefícios que um trocador de calor com aleta cortada da Alfa Laval pode trazer para você e mostrar como podemos ajudar a melhorar sua operação.
Serviço e peças de reposição
Você está procurando por peças de reposição ou serviços de campo? Podemos ajudar. Fale com um de nossos engenheiros de serviço de campo.
OEM spares available 24/7 in our ACE Webshop
Genuine spare parts for your ACE equipment are critical to uptime and profitability. At the Alfa Laval web shop, OEM quality spares are just a few clicks away. It’s easy to find the right part. Simply search using the serial number of your Alfa Laval ACE or, for any other brand of air-cooled heat exchanger, using the part specifications.
Modelos
Alfa Laval ACE Modelo A
- Seções verticais inclinadas e ventilador com ejeção vertical de ar
- As seções inclinadas fornecem um centro de gravidade otimizado para carregamento e transporte mais seguros
- Disponível com proteção de ventilador de alumínio de baixo peso para maior segurança na manutenção
Alfa Laval ACE Modelo C
- Seções verticais e ventilador com ejeção horizontal de ar
- Alternativa econômica e compacta para modelos de ejeção vertical de ar
- Fácil acesso ao cooler durante o serviço
Alfa Laval ACE Modelo E
- Seções horizontais e ventiladores com ejeção vertical de ar
- Disponível em um único ventilador para quatro configurações de ventilador
- Disponível com proteções de ventilador de alumínio de baixo peso para maior segurança na manutenção
- Unidade elétrica com capacidade para VFD para controle de ar e consumo de energia precisos
Alfa Laval ACE Modelo J
- Seções verticais e ventilador com ejeção vertical de ar
- Fácil acesso ao cooler durante o serviço
- O plenário direcional permite uma transição eficiente do fluxo de ar de horizontal para vertical
Alfa Laval ACE Modelo T
- Seções horizontais e ventiladores verticais com ejeção vertical de ar
- Disponível em configurações de um a cinco ventiladores
- Disponível com proteções de ventilador de alumínio de baixo peso para maior segurança na manutenção
- Largura relativamente estreita para facilitar o transporte
Alfa Laval ACE Modelo V
- Seções inclinadas com ventiladores horizontais e ejeção vertical de ar
- As células de ventilador de tiragem induzidas modulares permitem comprimentos de seção de até 18 m (60 pés)
- O design especial reduz os custos de transporte e espaço de plotagem em comparação com os desenhos de seções horizontais
- Ventiladores VFD padrão pré-instalados no sistema de controle, instalados na unidade, reduzem os custos operacionais
Alfa Laval Olmi Modelo G
- Design modular, garantindo pedidos e entregas rápidas
- Configurações flexíveis
- Projetado para facilitar o transporte em um caminhão normal ou em um contêiner de 40 pés
- Rápido e fácil de instalar
Alfa Laval Olmi API 661 Air Cooler
- Unidades projetadas sob encomenda para as aplicações mais difíceis
- Trabalha com temperaturas de até 400 °C (700 °F) e pressões de até 700 bar (10.000 psi)
- Disponível em muitos materiais, incluindo titânio
- Unidades modularizadas completamente pré-montadas
Case story: Upgrade brought lower operating costs and reduced noise levels
Substantial savings in power consumption as well as reduced noise and vibration levels were the results when the fans, motors and transmissions of a 60-cell system of air-cooled finned tube heat exchangers in a European fertilizer plant were upgraded. Alfa Laval Olmi´s service organization handled the entire upgrade from initial planning to installation.
Eficiência sustentável
Aumente a confiabilidade e a lucratividade com os trocadores de calor refrigerados a ar da Alfa Laval. Confira nosso folheto para saber como podemos ajudar você a melhorar a sustentabilidade da planta.
Como funciona
Working principle ACE Model E, Olmi API 661 and Olmi Model G
Working principle ACE Model A
The hot medium (e.g. hot water or lube oil) flows through the air-cooled finned tube heat exchanger within the large number of externally finned tubes. One or more fans force air across the tubes and the heat from the hot medium is transferred to the air. To maximize heat transfer, the tubes are equipped with fins that increase the area in contact with the air.
Alfa Laval offers a great variety of air-cooled finned tube heat exchanger designs in terms of:
- Number of fans
- Orientation of the fans (horizontal or vertical)
- Orientation of the tube sections (horizontal, vertical or sloped)
- Induced or forced draft
- Configurable plot sizes
Forced draft design
In air-cooled finned tube heat exchangers with a forced draft configuration the air passes the fan before it passes the finned tubes and the air is pushed through the tube bundles. The advantages with this include:
- The fan and belt is not exposed to the hot exhaust air, which increases component lifetimes.
- No temperature limit on the existing air.
- When the tube sections are horizontal, the fan is placed under the tubes, making access during service easier and costs for structure lower.
- Energy consumption is often lower as compared to induced draft units.
Induced draft design
In an air-cooled finned tube heat exchanger operating with induced draft the fan is placed after the tube sections, meaning air is pulled through the tube bundles. The advantages with this design are:
- A more even distribution of the air flow through the tube bundles.
- The risk of recirculating hot exhaust air is much lower thanks to a higher exit air velocity than in a forced-draft heat exchanger.
The combinations of forced/induced draft and the orientation of the fans and tube sections all have their individual advantages and ideal uses. Please contact your Alfa Laval representative for a discussion about the optimum solution for your specific conditions and application.
ACE - Princípio de operação
Olmi - Princípio de operação
Características únicas
ALOnsite™
Serviço real no local por engenheiros qualificados, em qualquer parte do mundo.
Discover our range of tailored air-cooling solutions
Air flow is nature’s own method of regulating temperature. Alfa Laval offers a wide range of energy-efficient high-performance systems for air-cooled heat exchange in industrial applications.